Siemens MAG 6000 I Ex de Meter | In Stock, 2h RFQ
  • Siemens SITRANS FM MAG 6000 I / 6000 I Ex de Transmitter - Original Stock
  • Siemens SITRANS FM MAG 6000 I / 6000 I Ex de Transmitter - Original Stock

Siemens SITRANS FM MAG 6000 I / 6000 I Ex de Transmitter - Original Stock

No.MAG-6000-I-EX-DE-SERIES

Factory-Direct Sourcing Advantage: Bypass long 12-14 week factory lead times with Hanyuzl's verified original stock inventory. Every unit ships factory-sealed with full SensorProm calibration chips, ATEX/FM certificates, and EN 10204 3.1 material certs.

  • ATEX Zone 1 / Ex de Flameproof: Two-chamber die-cast aluminum housing for harsh explosive service.
  • In-Zone Intrinsically Safe Programming: 3x20 display and keypad operable directly in hazardous areas without hot-work permits.
  • High Accuracy Signal Logic: ±0.2% ±1 mm/s precision with built-in batch control and NAMUR NE43 fault management.
  • Fast 2-Hour RFQ Guarantee: Submit your ordering code and receive an official technical quotation within 2 hours!
  • Siemens SITRANS FM MAG 6000 I / 6000 I Ex de Transmitter - Original Stock

Description

Quick Engineering Summary:
The Siemens SITRANS FM MAG 6000 I / 6000 I Ex de Flow Transmitter is built for chemical plant engineers, offshore platform operators, and hazardous process skid builders who need ATEX/FM Zone 1 explosion-proof flow measurement, direct in-zone keypad programming, and built-in batch control without hot-work permits or pipeline recalibration. Bypass 12-week factory lead times with Hanyuzl's verified original stock inventory and fast 2-hour technical RFQ response.

Siemens SITRANS FM MAG 6000 I / 6000 I Ex de Flow Transmitters

The Siemens SITRANS FM MAG 6000 I / 6000 I Ex de is a microprocessor-based electromagnetic flow transmitter housed in a die-cast aluminum two-chamber enclosure. Designed to pair with MAG 1100 F, MAG 3100 P, and MAG 5100 W flow sensors, it evaluates conductive liquid velocity down to ±0.2% ±1 mm/s accuracy in explosive gas and dust environments (ATEX Zone 1/21, FM Class 1 Div 2).

Siemens MAG 6000 I Ex de vs. Standard MAG 6000 Transmitters

Evaluating enclosure protection and safety certification is critical for hazardous area deployment. The table below outlines verified operational differences between the MAG 6000 I Ex de and standard utility transmitters:

Technical Feature SITRANS FM MAG 6000 I / Ex de Standard SITRANS FM MAG 6000
Enclosure Construction Robust die-cast aluminum two-chamber housing Polyamide or single-chamber compact aluminum
Hazardous Area Rating ATEX II 2(1)(2) GD EEx de [ia] ia [ib] IIC T6 / IECEx Standard non-Ex or FM Class 1 Div 2 only
In-Zone Interface Programming Intrinsically safe display & keypad (Direct Zone 1 operation) Requires enclosure removal or remote communicator
Calibrated Accuracy ±0.2% ±1 mm/s of actual volume flow ±0.25% ±1 mm/s of rate
NAMUR Compliance Profile NE21, NE32, NE43, NE53, NE70, NE131 compliant NE21, NE43 standard compliance
Power Supply Flexibility 24 V DC, 18-30 V DC, or 115-230 V AC (50/60 Hz) 12-24 V AC/DC or 115-230 V AC

Intrinsically Safe User Interface and Integrated Batch Control

Modifying batch parameters in hazardous locations usually requires plant shutdowns or hot-work permits. The MAG 6000 I Ex de incorporates an intrinsically safe 3x20 character backlit display and optical keypad. Operators adjust dosing setpoints, batch quantities, and diagnostic limits directly inside ATEX Zone 1 areas while maintaining full Ex de flameproof enclosure integrity.

Complex fluid metering requires active safety fallbacks. The transmitter output responds according to NAMUR NE43 guidelines, driving 4-20mA current signals below 3.6 mA or above 21.0 mA during fault states. Add-on communication modules enable seamless integration with HART, MODBUS RTU, PROFIBUS PA/DP, DeviceNet, and FOUNDATION Fieldbus protocol networks.

SensorProm Automated Reprogramming in Hazardous Zones

Transmitter replacement in hazardous plant loops can lead to manual configuration errors. The SensorProm memory chip mounts permanently on the sensor connection block, holding factory calibration data, sensor geometry, and customized setup profiles. When a replacement MAG 6000 I transmitter connects to the terminal box, it reads the SensorProm automatically upon power-up, restoring full operational accuracy without manual laptop re-programming.

Key Industrial Applications for SITRANS FM MAG 6000 I Ex de

  • Chemical & Petrochemical Processing: Precision batching and dosing of flammable solvents, acids, and organic chemical feeds in ATEX Zone 1 classified process areas.
  • Offshore Oil & Gas Platforms: Metering produced water, chemical injection fluids, and utility water in compact, high-vibration Ex de rated skid modules.
  • Pharmaceutical & Solvent Extraction: Continuous volumetric measurement in explosive alcohol and solvent synthesis lines requiring NAMUR NE131 functional safety verification.

Siemens MAG 6000 I / 6000 I Ex de Frequently Asked Questions

Q1: Can the MAG 6000 I Ex de transmitter keypad be programmed directly in hazardous areas?

A1: Yes. The keypad and backlit 3x20 character display are intrinsically safe (ia/ib). Technicians can program batch parameters or modify setup menus directly inside Zone 1 or Zone 21 hazardous locations without opening the Ex de enclosure or obtaining a hot-work permit.

Q2: What is the primary structural difference between MAG 6000 I and standard MAG 6000?

A2: The MAG 6000 I features a robust die-cast aluminum two-chamber housing designed for Ex de flameproof protection. Unlike the standard polyamide or compact aluminum MAG 6000, it separates the terminal connection compartment from the main electronics for safe field wiring in Ex-environments.

Q3: How does NE43 fault behavior management work during signal loss?

A3: The transmitter output follows NAMUR NE43 recommendations. Upon detecting sensor failure or air-pipe conditions, the 4-20mA current loop shifts below 3.6 mA or above 21.0 mA (selectable) to immediately flag critical system alarms to the plant DCS.

Q4: How does SensorProm technology support transmitter replacement in Ex zones?

A4: The SensorProm EEPROM resides on the flow sensor junction box. When replacing a damaged transmitter in a hazardous area, the new MAG 6000 I Ex de automatically downloads original factory calibration constants and pipe sizing upon initialization without manual data entry.

Sourcing Genuine Siemens MAG 6000 I Ex de Transmitters? Get a Fast Quote

Hanyuzl supplies factory-sealed Siemens SITRANS FM MAG 6000 I Ex de transmitters with original factory calibration certs, ATEX/FM approvals, and rapid global delivery.

Request 2-Hour Fast RFQ Quote

Get a Fast & Accurate Quote

Fill in your requirements below, and our engineers will respond within 24 hours.