Micro Motion CMF200M 2" DN50 Meter | Specs & RFQ In Stock
  • Emerson Micro Motion ELITE CMF200M 2 Inch DN50 Coriolis Meter
  • Emerson Micro Motion ELITE CMF200M 2 Inch DN50 Coriolis Meter

Emerson Micro Motion ELITE CMF200M 2 Inch DN50 Coriolis Meter

No.CMF200M300N2BAZEZZZ

The Emerson Micro Motion ELITE CMF200M is a high-precision 2 Inch (DN50) 316L stainless steel Coriolis flow meter engineered for critical custody transfer and process density control up to 1,450 psig (100 barg).

  • Fiscal Metering Precision: Delivers ±0.10% mass flow accuracy and ±0.0005 g/cm³ liquid density precision to prevent inventory losses.

  • Inline Smart Meter Verification: Enables zero-downtime structural tube diagnostics and health verification without interrupting flow.

  • 0 DN Straight Run Needed: Immune to fluid viscosity, air entrainment, and piping layout constraints for compact installation.

  • Quality & Support Guaranteed: Genuine original supply, 3.1 material traceability, fast technical dispatch, and direct RFQ support.

  • Emerson Micro Motion ELITE CMF200M 2 Inch DN50 Coriolis Meter

Description

Emerson Micro Motion ELITE CMF200M Coriolis Meter (2 Inch DN50): Technical Specification & Selection Guide

The Emerson Micro Motion ELITE CMF200M (2 Inch / DN50, 316L Stainless Steel) is engineered for process engineers reviewing our Industrial Flow Meter Guide: Selection & Procurement who cannot afford volume-to-mass conversion errors in high-value custody transfer, precision chemical batching, or strict density control.

Micro Motion ELITE CMF200M (2 Inch / DN50)
Direct Mass Flow, Density & Temperature Sensor
↓
Custody Transfer & Batching
±0.10% Mass Flow / ±0.0005 g/cc
Inline Smart Meter Verification
Continuous Tube Integrity Check

CMF200M Technical Specifications & 2-Inch Line Performance Limits

Performance Metric Standard Specification (CMF200M 316L) Optional High-Precision Upgrade Practical Plant Application Impact
Nominal Line Size 2 Inch (DN50) Flanged / Hygienic / Weld connections Fits standard 2-inch process headers directly
Nominal Mass Flow Rate 1,200 lb/min (32,700 kg/h) Max capacity up to 3,200 lb/min (87,100 kg/h) Prevents line choking during batch transfers
Liquid Mass Flow Accuracy ±0.10% of rate ±0.05% of rate Eliminates mass balance loss in fiscal metering
Liquid Density Accuracy ±0.0005 g/cm³ (±0.5 kg/m³) ±0.0002 g/cm³ (±0.2 kg/m³) Eliminates fluid blending errors in real time
Gas Mass Flow Accuracy ±0.35% of rate ±0.20% repeatability Ensures accurate mass accounting for industrial gases
Operating Temperature -400°F to 662°F (-240°C to 350°C) Cryogenic to High-Temp variants Handles cryogenic LNG or hot chemical fluids
Max Working Pressure (316L) Up to 1,450 psig (100 barg) Special Super-Duplex/C-22 ratings higher Safe operation in high-pressure header lines
Wetted Material 316L Stainless Steel C-22 Nickel Alloy / Super-Duplex Excellent corrosion resistance for process liquids
Safety Approvals CSA, ATEX, IECEx, NEPSI, IP66/67 SIL2 / SIL3, Marine, Custody Transfer Fully compliant with explosion-proof site standards

Stopping Inventory Losses in DN50 Custody Transfer and Batching Lines

In 2-inch process pipelines, minor flow measurement drift quickly accumulates into tens of thousands of dollars in unmetered inventory. Volumetric meters rely on secondary pressure and temperature transmitters to calculate mass, introducing stacked tolerances whenever line conditions fluctuate.

The Micro Motion CMF200M directly measures mass flow by capturing the Coriolis force exerted by the fluid on its twin curved sensor tubes. Combined with a liquid density accuracy of ±0.0005 g/cm³ (upgradable to ±0.0002 g/cm³), this meter eliminates calculation errors caused by fluid expansion, bubbles, or temperature spikes in storage tanks and loading skids.

Zero-Downtime Smart Meter Verification for Continuous Process Integrity

Removing a 2-inch Coriolis flow meter from a live line for calibration means halting production, draining pipes, and paying heavy labor costs.

With Emerson’s integrated Smart Meter Verification (SMV), maintenance teams run total structural and electronic integrity checks in less than 90 seconds while the fluid continues to flow. The transmitter evaluates tube stiffness, drive voltage, and zero stability without breaking pipe flanges or interrupting line operations. This allows plants to safely extend physical calibration intervals from annually to every 3 to 5 years without risking compliance audits.

Technical Comparison: Micro Motion CMF200M vs. Vortex & Magmeters (Explore our full range of Coriolis Mass Flow Meters for other pipe sizes)

Selection Criteria CMF200M 2-Inch Coriolis 2-Inch Industrial Vortex Flowmeter 2-Inch Electromagnetic Meter
Primary Measurement Direct Mass Flow, Density, Temp Volumetric Flow Rate Volumetric Flow Rate
Fluid Capability Liquids, Gases, Slurries, Viscous Steam, Clean Gas, Low-viscosity Liquid Conductive Liquids Only
Straight Pipe Run Requirement 0 DN (No straight run needed) 10–20 DN Upstream required 5 DN Upstream required
Viscosity & Air Bubble Sensitivity Immune (Measures pure mass) High viscosity damps vortex signals High solids/bubbles cause signal noise
Primary Engineering Value Fiscal custody transfer, precise mass batching Utility steam headers, simple gas flow Water, wastewater, basic chemical dosing

People Also Ask (PAA) & Engineering Support

How does CMF200M Smart Meter Verification reduce annual maintenance costs?

Smart Meter Verification tests the sensor tube's physical stiffness and drive electronics in-line without taking the meter off the pipe. This reduces unnecessary pulls for lab calibrations, saving hours of maintenance labor and process downtime.

Is 316L Stainless Steel suitable for all process chemicals in a CMF200M?

316L Stainless Steel is ideal for standard industrial chemicals, water, steam, fuels, and food-grade processes. However, if your application involves wet chlorine, sour gas (H2S), or aggressive acids, consider specifying Hastelloy C-22 or Super-Duplex variants instead.

Can the Micro Motion CMF200M handle high-viscosity liquids or slurries?

Yes. Unlike vortex meters that require low viscosity to form vortices, or turbine meters that get clogged, the CMF200M's curved dual-tube design measures mass flow independently of fluid viscosity, Reynolds number, or suspended solid content.

Need a technical cross-reference, sizing calculation based on our Industrial Flow Meter Guide, or a direct quote for the Emerson Micro Motion Series? Contact our technical engineering team today.

Get a Fast & Accurate Quote

Fill in your requirements below, and our engineers will respond within 24 hours.
Name *
Email *
Message
Get a free Quote
Name *
Email *
Message
Message Us