The Emerson Micro Motion ELITE CMF200M is a high-precision 2 Inch (DN50) 316L stainless steel Coriolis flow meter engineered for critical custody transfer and process density control up to 1,450 psig (100 barg).
Fiscal Metering Precision: Delivers ±0.10% mass flow accuracy and ±0.0005 g/cm³ liquid density precision to prevent inventory losses.
Inline Smart Meter Verification: Enables zero-downtime structural tube diagnostics and health verification without interrupting flow.
0 DN Straight Run Needed: Immune to fluid viscosity, air entrainment, and piping layout constraints for compact installation.
Quality & Support Guaranteed: Genuine original supply, 3.1 material traceability, fast technical dispatch, and direct RFQ support.
The Emerson Micro Motion ELITE CMF200M (2 Inch / DN50, 316L Stainless Steel) is engineered for process engineers reviewing our Industrial Flow Meter Guide: Selection & Procurement who cannot afford volume-to-mass conversion errors in high-value custody transfer, precision chemical batching, or strict density control.
| Performance Metric | Standard Specification (CMF200M 316L) | Optional High-Precision Upgrade | Practical Plant Application Impact |
| Nominal Line Size | 2 Inch (DN50) | Flanged / Hygienic / Weld connections | Fits standard 2-inch process headers directly |
| Nominal Mass Flow Rate | 1,200 lb/min (32,700 kg/h) | Max capacity up to 3,200 lb/min (87,100 kg/h) | Prevents line choking during batch transfers |
| Liquid Mass Flow Accuracy | ±0.10% of rate | ±0.05% of rate | Eliminates mass balance loss in fiscal metering |
| Liquid Density Accuracy | ±0.0005 g/cm³ (±0.5 kg/m³) | ±0.0002 g/cm³ (±0.2 kg/m³) | Eliminates fluid blending errors in real time |
| Gas Mass Flow Accuracy | ±0.35% of rate | ±0.20% repeatability | Ensures accurate mass accounting for industrial gases |
| Operating Temperature | -400°F to 662°F (-240°C to 350°C) | Cryogenic to High-Temp variants | Handles cryogenic LNG or hot chemical fluids |
| Max Working Pressure (316L) | Up to 1,450 psig (100 barg) | Special Super-Duplex/C-22 ratings higher | Safe operation in high-pressure header lines |
| Wetted Material | 316L Stainless Steel | C-22 Nickel Alloy / Super-Duplex | Excellent corrosion resistance for process liquids |
| Safety Approvals | CSA, ATEX, IECEx, NEPSI, IP66/67 | SIL2 / SIL3, Marine, Custody Transfer | Fully compliant with explosion-proof site standards |
In 2-inch process pipelines, minor flow measurement drift quickly accumulates into tens of thousands of dollars in unmetered inventory. Volumetric meters rely on secondary pressure and temperature transmitters to calculate mass, introducing stacked tolerances whenever line conditions fluctuate.
The Micro Motion CMF200M directly measures mass flow by capturing the Coriolis force exerted by the fluid on its twin curved sensor tubes. Combined with a liquid density accuracy of ±0.0005 g/cm³ (upgradable to ±0.0002 g/cm³), this meter eliminates calculation errors caused by fluid expansion, bubbles, or temperature spikes in storage tanks and loading skids.
Removing a 2-inch Coriolis flow meter from a live line for calibration means halting production, draining pipes, and paying heavy labor costs.
With Emerson’s integrated Smart Meter Verification (SMV), maintenance teams run total structural and electronic integrity checks in less than 90 seconds while the fluid continues to flow. The transmitter evaluates tube stiffness, drive voltage, and zero stability without breaking pipe flanges or interrupting line operations. This allows plants to safely extend physical calibration intervals from annually to every 3 to 5 years without risking compliance audits.
| Selection Criteria | CMF200M 2-Inch Coriolis | 2-Inch Industrial Vortex Flowmeter | 2-Inch Electromagnetic Meter |
| Primary Measurement | Direct Mass Flow, Density, Temp | Volumetric Flow Rate | Volumetric Flow Rate |
| Fluid Capability | Liquids, Gases, Slurries, Viscous | Steam, Clean Gas, Low-viscosity Liquid | Conductive Liquids Only |
| Straight Pipe Run Requirement | 0 DN (No straight run needed) | 10–20 DN Upstream required | 5 DN Upstream required |
| Viscosity & Air Bubble Sensitivity | Immune (Measures pure mass) | High viscosity damps vortex signals | High solids/bubbles cause signal noise |
| Primary Engineering Value | Fiscal custody transfer, precise mass batching | Utility steam headers, simple gas flow | Water, wastewater, basic chemical dosing |
Smart Meter Verification tests the sensor tube's physical stiffness and drive electronics in-line without taking the meter off the pipe. This reduces unnecessary pulls for lab calibrations, saving hours of maintenance labor and process downtime.
316L Stainless Steel is ideal for standard industrial chemicals, water, steam, fuels, and food-grade processes. However, if your application involves wet chlorine, sour gas (H2S), or aggressive acids, consider specifying Hastelloy C-22 or Super-Duplex variants instead.
Yes. Unlike vortex meters that require low viscosity to form vortices, or turbine meters that get clogged, the CMF200M's curved dual-tube design measures mass flow independently of fluid viscosity, Reynolds number, or suspended solid content.
Need a technical cross-reference, sizing calculation based on our Industrial Flow Meter Guide, or a direct quote for the Emerson Micro Motion Series? Contact our technical engineering team today.