JD4 Pump-Suction 4-Gas Detector | Ex ib In Stock RFQ
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S

JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S

No.JD4-PUMP-4GAS
In-stock JD4 pump-suction multi-gas detector for simultaneous CH4, CO, O2, and H2S monitoring in confined spaces and coal mines. Built-in vacuum pump, infrared & electrochemical sensors, Ex ib I Mb & IP65 certified. 48h dispatch & 2h RFQ!
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S
  • JD4 Pump-Suction Multi-Gas Detector | CH4 CO O2 H2S

Description

Quick Summary: The JD4 pump-suction multi-gas detector is built for underground coal mine safety teams, confined space entry inspectors, and petrochemical operators who need simultaneous CH4, CO, O2, and H2S monitoring plus ambient temperature and humidity readings. It solves slow diffusion lag in deep shafts and narrow pipelines with an integrated miniature vacuum sampling pump, infrared + electrochemical sensors, and Ex ib I Mb / IP65 protection. Hanyu Zhilian maintains verified stock for 48-hour global dispatch.

JD4 Pump-Suction Multi-Gas Detection Alarm (CH4, CO, O2, H2S)

1. Active Pump-Suction Sampling for Confined Space and Deep Shaft Safety

Passive diffusion gas monitors react too slowly when checking deep manholes, sealed mine headings, or overhead piping galleries before worker entry. The JD4 integrates a miniature vacuum sampling pump to draw remote gas samples directly into its sensor chamber for rapid response. Combining a long-life infrared methane sensor (≥5 years) with high-selectivity electrochemical cells for CO, O2, and H2S, it delivers simultaneous 4-gas readings alongside ambient temperature and relative humidity.

Figure 1: Structural layout of JD4 featuring top LED alarm indicator, TFT color display, audible buzzer, and tactile navigation keys.

2. TFT Color Interface, 5,000-Record Data Logging, and Type-C Connectivity

Driven by an embedded microcontroller, the JD4 displays real-time gas curves, battery voltage, and clock status on a high-contrast TFT color screen. Operators can configure custom low/high alarm thresholds that trigger a ≥75 dB audible buzzer alongside flashing visual alarms. The unit stores up to 5,000 historical measurement records internally and supports wireless Wi-Fi data transfer plus universal USB Type-C charging.

Figure 2: Core functional capabilities including intelligent calibration, active pump sampling, 5,000-record storage, and IP65 enclosure.

3. Multi-Gas Sensor Range, Accuracy, and System Specifications

Target Gas Measurement Range Intrinsic Error (by Span) Resolution Response / Life
Methane (CH4) (0.00 ~ 100)% VOL 0.00~1.00%: ±0.06%
1.00~100%: ±6% of true value
0.01% (<10%)
0.1% (≥10%)
≤25 s / ≥5 yrs
Carbon Monoxide (CO) (0 ~ 1000) ppm 0~20: ±2 ppm | 20~100: ±4 ppm
100~500: ±5% | 500~1000: ±6%
1 ppm ≤45 s / ≥2 yrs
Oxygen (O2) (0.0 ~ 30.0)% VOL 0.0~5.0% & 25.0~30.0%: ±3% F.S.
5.0~25.0%: ±0.5% VOL
0.1% VOL ≤35 s / ≥2 yrs
Hydrogen Sulfide (H2S) (0 ~ 100) ppm 0~49 ppm: ±3 ppm
50~100 ppm: ±10% of measured value
1 ppm ≤45 s / ≥2 yrs
Explosion-Proof & Ingress Ex ib I Mb (Intrinsically safe for underground mines) | IP65 dust/water resistant
Official Certificates Coal Mine Safety MA No.: MFA240187 | Ex Certificate No.: CQEx24.0906X
Battery & Runtime 18465 / 3.7V / 4.0Ah Li-Mn rechargeable battery pack | Continuous runtime ≥10 hours
Alarm & Dimensions Audible sound intensity ≥75 dB + red LED strobe | Housing size: 168.5 × 76.1 × 54.7 mm
Standard & Optional Kit Standard: Dedicated Type-C charger | Optional: BZC-50 Intelligent Instrument Charging Management System

4. Verified Field Applications Across Hazardous Industries

Certified under MA (MFA240187) and Ex ib I Mb (CQEx24.0906X) safety standards, the JD4 multi-gas detector is built for rugged industrial inspection routines:

  • Underground Coal Mining: Pre-shift heading inspections, return airway toxic gas checks (CO/H2S), and high-concentration CH4 monitoring.
  • Metallurgical Operations: Blast furnace gas leakage detection and converter area carbon monoxide safety patrols.
  • Chemical & Petrochemical Plants: Tank farm confined space entry testing and toxic H2S/flammable vapor verification.
  • Offshore & Onshore Oil Drilling: Wellhead sour gas (H2S) warning and oxygen deficiency monitoring in mud pits.
Figure 3: Deployed across underground coal mines, metallurgical plants, chemical refineries, and oil drilling rigs.

Frequently Asked Questions (FAQ) - JD4 Multi-Gas Detector

Q1: Which gases and environmental parameters can the JD4 detect simultaneously?

The JD4 simultaneously measures four gases—Methane (CH4: 0–100%), Carbon Monoxide (CO: 0–1000 ppm), Oxygen (O2: 0–30%), and Hydrogen Sulfide (H2S: 0–100 ppm)—while displaying real-time ambient temperature and humidity on its TFT screen.

Q2: Why is a pump-suction multi-gas detector better for confined spaces than a diffusion model?

The JD4 uses an internal miniature vacuum sampling pump to actively pull gas from deep shafts, pipelines, or manholes via a sampling hose, allowing workers to verify toxic or explosive gas levels before entering hazardous zones.

Q3: How long does the JD4 battery last on a single charge?

Equipped with a 3.7V / 4.0Ah lithium-manganese battery pack and USB Type-C charging interface, the JD4 operates continuously for at least 10 hours per full charge, covering a full underground shift.

Q4: Does the JD4 support fleet charging management and data export?

Yes, the JD4 stores up to 5,000 historical test records with Wi-Fi data transmission and is compatible with the optional BZC-50 Intelligent Instrument Charging Management System for multi-unit mine lamp room deployment.

Sourcing JD4 Pump-Suction Multi-Gas Detectors?

Hanyu Zhilian supplies factory-certified JD4 4-gas analyzers (Ex ib I Mb / IP65) with verified stock and optional BZC-50 charging racks. Receive a formal quote within 2 hours.

Request Stock Quotation & Specs

Get a Fast & Accurate Quote

Fill in your requirements below, and our engineers will respond within 24 hours.
Name *
Email *
Message
Get a free Quote
Name *
Email *
Message
Message Us