Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)

Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)

Prosonic Flow P 500 offers non-invasive liquid measurement up to 550°C. Features FlowDC for short inlet runs (2xDN) and Heartbeat Technology. Zero process interruption.
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)
  • Endress+Hauser Prosonic Flow P 500 | Clamp-on Ultrasonic Flowmeter (550°C)

Description

Zero Maintenance, Zero Process Interruption

The Ultimate Non-Invasive Solution for Extreme Temperatures

The Prosonic Flow P 500 is the premier industrial choice for measuring conductive and non-conductive liquids without ever cutting the pipe. Its sophisticated clamp-on design ensures your process remains closed, pressurized, and safe, regardless of liquid density or corrosiveness.

Available via Hanyu Zhilian, the P 500 stands out with its patented FlowDC function, which compensates for flow profile disturbances—maintaining high accuracy even with a minimal inlet run of only 2 x DN. Whether you are managing cryogenic fluids or extreme high-temperature processes up to 550 °C (1022 °F), the P 500’s specialized coupling pads ensure a maintenance-free life cycle without the need for periodic re-greasing or sensor adjustment.


Technical Specifications at a Glance

Feature Technical Data
Measuring Principle Ultrasonic Clamp-on (Time-of-flight)
Pipe Size Range DN 15 to DN 4000 (0.5" to 160")
Max. Temperature Up to 550 °C (1022 °F)
Straight Run Required Minimal 2 x DN (with integrated FlowDC)
Accuracy Up to ±0.5% (with field calibration) / ±2% (standard)
Safety Ratings SIL 2/3 (IEC 61508), ATEX, IECEx, Class I Div 1
Materials Stainless Steel housings with high-temp coupling pads

Strategic Advantages: Why Prosonic Flow P 500 is the Smart Investment

  • Non-Invasive Excellence: Clamps onto the outside of the pipe. No risk of leaks, no pressure drop, and absolutely no need to shut down your production line for installation.

  • FlowDC Technology: Solve the "short straight pipe" problem. FlowDC allows the P 500 to maintain accuracy in tight spaces where traditional meters would fail due to turbulence.

  • High-Temperature Specialist: While most clamp-on meters fail at 200°C, the P 500 thrives in refinery and solar thermal applications up to 550°C using specialized sensor mounting.

  • Heartbeat Technology™: Permanent self-diagnostics and traceable verification without process interruption. Ensure your measurement point is compliant with safety standards 24/7.

  • Hanyu Supply & Selection: We provide expert technical selection for the P 500 to ensure the sensors and mounting hardware are perfectly matched to your pipe material and medium.


Application Case: High-Temp Refinery Flow Optimization

The Challenge: A refinery needed to monitor the flow of hot hydrocarbons at 480 °C. Traditional inline meters were rejected due to the immense cost of plant shutdown and the risk of flange leaks at such temperatures.

The Hanyu Solution: The operator deployed the Prosonic Flow P 500 with the High-Temperature sensor package from hanyuzl.com.

  • The Result: Sensors were clamped onto the live pipe in under two hours.

  • The Impact: Thanks to FlowDC, the meter provided stable data despite being installed near a pipe bend. Heartbeat Technology now provides the refinery with documented proof of sensor health, ensuring long-term safety and zero maintenance for the next scheduled turnaround.


Frequently Asked Questions (FAQ)

Q1: Does the signal degrade over time on high-temperature pipes?
A: No. Unlike traditional sensors that use grease, the P 500 high-temp sensors use solid coupling pads that do not dry out or degrade, ensuring signal stability for years.

Q2: Can the P 500 be used on very large pipes like DN 2000?
A: Absolutely. The P 500 is cost-effective for large diameters (up to DN 4000). While the cost of inline meters increases exponentially with size, the clamp-on P 500 remains an affordable high-performance option.

Q3: How do I manage the measurement data?
A: The P 500 is fully compatible with modern digital protocols. For integrated facility management, it can be paired with the  [SICK Flow-X High-Precision Flow Computer]. for fiscal-level reporting or integrated into your SCADA via HART/Modbus.

Q4: How does Hanyu Zhilian handle my technical inquiries?
A: We strictly follow our Privacy Policy. All project details shared via hanyuzl.com are used exclusively for technical consulting and order fulfillment.

Get a Fast & Accurate Quote

Fill in your requirements below, and our engineers will respond within 24 hours.
Name*
Email*
Message
Get a free Quote
Name*
Email*
Message
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.