The Micro Motion ELITE CMF010M is the most widely used high-precision 1/10-inch (DN2) Coriolis meter for low-flow applications. Crafted from premium 316L Stainless Steel, it delivers unparalleled measurement sensitivity and stability. Whether you are performing high-value chemical dosing, catalyst injection, or precision laboratory research, the CMF010M provides the repeatable accuracy (up to ±0.05%) required for critical process control.
Peak Micro-Flow Sensitivity: Specially designed to maintain high accuracy even at extremely low flow rates where other meters fail.
Exceptional Measurement Confidence: Achieve the highest immunity to vibration, pressure fluctuations, and environmental effects.
Smart Meter Verification (SMV): Real-time, in-process diagnostic tool that verifies sensor health and tube integrity without stopping the flow.
Versatile Process Capability: Reliable performance across temperatures from -400°F to 662°F (-240°C to 350°C) and pressures up to 1,812 psig (125 barg).
Robust 316L SST Construction: Offers excellent durability and broad chemical compatibility for most standard industrial fluids.
Global Hazardous Approvals: Fully certified by CSA, ATEX, IECEx, and NEPSI for use in high-risk environments, with SIL2/SIL3 safety ratings.
Multivariable Output: Simultaneously measures mass flow, volume flow, density, and temperature from a single compact device.
| Feature | Specification Details |
| Line Size | 1/10 Inch (DN2) |
| Wetted Material | 316L Stainless Steel |
| Liquid Mass Accuracy | ±0.10% (Standard) / ±0.05% (Optional) |
| Liquid Density Accuracy | ±0.0005 g/cm³ (±0.5 kg/m³) |
| Gas Mass Accuracy | ±0.35% of rate |
| Max Working Pressure | 1,812 psig (125 barg) |
| Safety Certification | SIL 2 / SIL 3 Capable |
Q: Can the CMF010M handle entrained gas in small doses?
A: Yes, the ELITE series electronics are designed to provide stable measurement even in challenging two-phase flow conditions, ensuring batch consistency.
Q: Does the CMF010M require straight pipe runs?
A: No. One of the greatest advantages of the Micro Motion Coriolis design is that it does not require straight runs or flow conditioning, allowing for extremely compact skid designs.
Q: How often should I run Smart Meter Verification?
A: SMV can be run as frequently as needed (daily, weekly, or before a critical batch) to ensure the meter is performing to factory specifications without needing to pull it from the line.