Endress+Hauser PMD50 DP Transmitter | In Stock Quote
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter

Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter

A budget-optimized, heavy-duty workhorse engineered for reliable flow, tank level, and filter monitoring. Featuring a robust metal isolating membrane and standard 4-20mA HART protocol, the PMD50 balances foundational process accuracy with an economical CAPEX framework. Ready-to-install with pressure-tested manifold configurations.
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter
  • Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter

Description

Endress+Hauser Deltabar PMD50 Differential Pressure Transmitter

The Endress+Hauser Deltabar PMD50 is a high-efficiency differential pressure transmitter engineered for continuous process measurement in industrial utility loops, water treatment plants, and secondary chemical processing lines. Featuring a piezoresistive sensor paired with a high-resilience metallic isolating diaphragm (316L, AlloyC, or Gold-plated), the PMD50 delivers reference accuracy up to ±0.055% and 10-year long-term stability of ±0.25% URL. It provides cost-conscious plant managers with robust 4-20mA HART 7 telemetry, SIL 2/3 functional safety compliance, and intuitive software-guided commissioning without forcing the high CAPEX of heavy-duty custody transfer units.

⚡ Quick Answer: Is Deltabar PMD50 Right for Your Process Loop?

The Deltabar PMD50 is the optimal budget-friendly choice if you require reliable hydrostatic level, differential flow, or filter monitoring up to 40 bar span in standard industrial environments. It provides full HART 7 connectivity and robust overpressure protection up to 375 bar. For extreme custody transfer accuracy or Ethernet-APL architectures, consider upgrading to the premium PMD75B.

👉 Procurement Status: Factory-Fresh Stock Available. Request 2-Hour Fast RFQ Quote & Matrix Sheet.

1. Technical Specifications & Operational Envelope

Key metrological parameters for the Endress+Hauser PMD50 differential pressure transmitter:

Metrological Parameter Engineered Performance Details
Reference Accuracy Standard: ±0.065% | Platinum Spec Upgrade: ±0.055%
Measuring Range Span 100 mbar to 40 bar (1.45 psi to 580 psi) fully adjustable span
Long-Term Drift Stability ±0.25% of URL over a full 10-year operational lifecycle
Process Temperature Limits -40°C to +110°C (-40°F to +230°F) direct | Up to +400°C via remote seals
Overpressure Limit (MWP) Single-sided overpressure safe up to 375 bar (5,625 psi)
Communication Protocol 4-20mA HART (HART 7 ready) loop telemetry
Functional Safety Certification IEC 61508 Certified SIL 2 (Single) or SIL 3 (Redundant Architecture)

2. CAPEX & Performance Comparison: PMD50 vs. PMD75B

Balance your plant procurement budget by deploying premium instruments only where necessary:

Feature / Specification Standard Deltabar PMD50 (This Model) Premium Deltabar PMD75B (Advanced)
Target Application Scope Standard process lines, filtering units & utilities Critical custody transfer, high-pressure severe duty
Max. Reference Accuracy Up to ±0.055% (Platinum Option) Up to ±0.035% (Ultra-Platinum Spec)
Embedded Diagnostics NAMUR NE107 Standard Status Diagnostics Advanced Heartbeat Technology (Predictive Maintenance)
Industrial Network Options Standard 4-20mA HART protocol Ethernet-APL, PROFINET, PROFIBUS PA & Bluetooth
Procurement CAPEX Profile Highly Economical / Budget-Friendly Premium Grade / High-Investment Node

3. Advantages, Limitations & Target Applications

✅ Key Advantages (Pros)

  • Cost-Optimized Reliability: Delivers essential industrial accuracy (±0.055%) without forcing premium feature overhead.
  • Hydrogen Barrier Protection: Optional Gold-plated or AlloyC membranes prevent hydrogen permeation in sour chemical service.
  • Fast Loop Commissioning: Onboard software-guided wizard eliminates manual zero-point calibration errors.
  • High Overpressure Defense: Single-sided overpressure protection up to 375 bar prevents diaphragm rupture during line spikes.

âš ī¸ Application Limitations (Cons)

  • No Ethernet-APL: Limited to 4-20mA HART protocol; not suitable for high-speed Ethernet fieldbus architectures.
  • Not Fully Hygienic Flush: Uses standard threaded/flanged impulse connections rather than gap-free EHEDG flush seals (for hygienic applications, choose PMD63B).

4. Engineering Decision Tree for PMD50 Selection

Follow this logic flow to confirm if the Deltabar PMD50 fits your process parameters:

  • 🔍 Step 1: What is the primary purpose of the measurement loop?
    • Standard tank level, orifice flow, or filter differential pressure → Proceed to Step 2.
    • Fiscal custody transfer or ultra-high precision metering → Select PMD75B.
  • 🔍 Step 2: Is the process environment sanitary (FDA/EHEDG food or biotech)?
    • YES → Select aseptic flush model PMD63B Hygienic.
    • NO → Proceed to Step 3.
  • 🔍 Step 3: Is 4-20mA HART communication sufficient for your DCS/PLC?
    • YESDeploy Deltabar PMD50 for maximum CAPEX savings.

5. Field MRO & Instrument Replacement Checklist

Replacing a failing legacy differential pressure transmitter (such as an older E+H PMD235, PMD70, or third-party 3051CD unit)? To prevent costly piping rework and commissioning delays, our application technicians advise verifying these 4 parameters prior to order submission:

📋 Pre-Procurement Field Checklist:

  • â˜‘ī¸ Process Flange & Oval Adapter Specs: Confirm process connection thread standard (e.g. 1/4 - 18 NPT or 1/2 - 14 NPT) and mounting bolt center distance.
  • â˜‘ī¸ Static Line Pressure Rating: Verify that maximum system working pressure (MWP) does not exceed the transmitter range limit (up to 40 bar).
  • â˜‘ī¸ Wetted Diaphragm Compatibility: Specify AlloyC or Gold-plated options if acid gas or hydrogen diffusion risks exist.
  • â˜‘ī¸ Explosion-Proof Area Certification: Verify whether your installation zone requires ATEX, IECEx, or FM intrinsically safe approvals.

6. Commercial & Procurement FAQ

Q: Can the Deltabar PMD50 be used for vacuum applications?

A: Yes, the device offers reliable vacuum resistance down to 25 mbar absolute (0.0375 psi), making it suitable for low-pressure distillation column monitoring and vacuum-sealed storage tanks.

Q: What membrane material should I choose for corrosive gases?

A: For severe chemical or acid gas service, we highly recommend upgrading from standard 316L Stainless Steel to AlloyC or Gold-coated membranes to maximize the transmitter's lifecycle against hydrogen permeation.

Q: What is the typical lead time and supply guarantee from Hanyu Zhilian?

A: We maintain factory-fresh stock for fast-moving PMD50 configurations to bypass standard factory delays. Quotations are dispatched within 2 hours, and orders ship globally via DHL/FedEx within 3-5 business days.


🔗 Pressure Transmitter Center Knowledge Graph

Explore interconnected instrumentation technical hubs, model comparisons, and selection guides across our network:

Need a Technical Specification & Price Quote for PMD50?

We provide competitive pricing, full material traceability (EN 10204 3.1), and expedited global shipping for genuine Endress+Hauser instrumentation.

âąī¸ Get Direct RFQ Quote & Price Matrix Within 2 Hours

Get a Fast & Accurate Quote

Fill in your requirements below, and our engineers will respond within 24 hours.
Name *
Email *
Message
Get a free Quote
Name *
Email *
Message
Message Us