CJG10(A) Optical Methane Detector | Ex ia Gas Meter RFQ
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer

CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer

No.CJG10A-OPT-010
Direct factory supply of CJG10(A) optical methane detector for coal mines. Range 0–10% CH4, Ex ia I Ma certified, 0.8kg portable design. Fast 48h dispatch.
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer
  • CJG10(A) Portable Optical Methane Detector | Ex ia I Ma Gas Interferometer

Description

Quick Summary: The CJG10(A) optical methane detector (Range: 0–10% CH4) is designed for underground coal mine safety inspectors and tunnel ventilation engineers who need accurate, non-electronic CH4 spot-checks. It solves electronic sensor drift and poisoning in high-sulfur mines with an Ex ia I Ma intrinsically safe optical design. Hanyu Zhilian provides factory-verified stock with 48-hour global dispatch.

CJG10(A) Portable Optical Interference Methane Detector

1. Optical Physical Measurement for Underground Methane Hazards

Standard electronic catalytic sensors easily drift or poison when exposed to high-sulfur and high-humidity underground atmospheres. The CJG10(A) uses pure optical refraction physics to measure ambient methane concentration without chemical sensor wear. This instrument allows mine safety inspectors and tunnel ventilation engineers to obtain reliable CH4 readings in active coal seams and confined industrial spaces.

Figure 1: Physical layout of CJG10(A) showing the eyepiece reticle, scale window, and zero-adjust handwheel.

2. Optical Principle and Micrometer Scale Precision

The meter operates by comparing light interference fringes generated between a reference air chamber and a sample gas chamber. Sample air drawn through the 1500mm rubber hose passes through an absorption tube set to remove moisture and CO2 before optical evaluation. Operators read integer percentages through the 0.5% main reticle and fine-tune decimal values down to 0.02% using the micrometer dial.

Technical Parameter CJG10(A) Verification Data
Measurement Range (0 ~ 10)% CH4 methane concentration
Intrinsic Error (by Range) 0~1%: ±0.05% | 1~4%: ±0.10% | 4~7%: ±0.20% | 7~10%: ±0.30%[cite: 19]
Scale & Division Value Eyepiece reticle min: 0.5% | Micrometer dial range: 0~1% (Min division: 0.02%)[cite: 19]
Explosion-Proof Mark Ex ia I Ma (Intrinsically safe for underground gassy mines)[cite: 19]
Power & Dimensions Single YLMP18650 Li-ion battery (3.7V) | Size: 168.5×97×52.4 mm | Weight: 0.8 kg[cite: 19]

3. Standard Field Kit and Portable Design

Weighing only 0.8 kg with a compact aluminum alloy housing, the CJG10(A) is built for single-handed carrying during long underground inspection shifts. Each unit ships as a complete field kit inside a protective leather case with shoulder straps. The standard configuration includes a dedicated charger, rubber squeezing bulb, chemical absorption tube, replacement bulb, and a 1500mm sampling tube[cite: 19].

Figure 2: Complete factory configuration with leather case, charging adapter, absorption tubes, and sampling line[cite: 19].

4. Verified Applications in Underground Mining and Industry

Backed by its Ex ia I Ma intrinsic safety certification, this optical methane detector is widely deployed in hazardous industries:

  • Underground Coal Mines: Face gas inspection, return airway monitoring, and goaf boundary checks.
  • Offshore Petroleum Extraction: Methane pocket verification on drilling rigs and separation skids.
  • Chemical Processing Plants: Flammable gas leakage checking in enclosed valve vaults and galleries.
Figure 3: Typical operational environments including underground coal seams, offshore platforms, and chemical plants.

Frequently Asked Questions (FAQ) - CJG10(A)

Q1: What is the measurement accuracy of the CJG10(A) optical methane detector?

The CJG10(A) measures CH4 concentrations from 0 to 10%. It features an intrinsic error of ±0.05% in the 0–1% span, ±0.10% in the 1–4% span, ±0.20% in the 4–7% span, and ±0.30% in the 7–10% span.

Q2: Is the CJG10(A) certified for underground coal mine safety?

Yes, the CJG10(A) carries the Ex ia I Ma intrinsic safety certification, making it fully compliant for hazardous underground coal seams and gassy environments.

Q3: Why choose an optical methane detector over electronic sensors?

Unlike electronic catalytic sensors that easily drift or suffer chemical poisoning in high-sulfur and high-humidity environments, the CJG10(A) relies on light refraction physics, eliminating sensor wear and frequent recalibration.

Q4: What accessories are included in the standard CJG10(A) field kit?

Each unit comes as a complete field kit containing a protective leather case with shoulder strap, wall charger, rubber squeezing bulb, chemical absorption tube, spare light bulb, and a 1500mm sampling rubber tube.

Sourcing CJG10(A) Optical Methane Detectors?

Hanyu Zhilian maintains verified factory-original stock for CJG10(A) gas interferometers with complete accessory kits. Get a guaranteed 2-hour technical RFQ response.

Request Stock Quotation & Specs

Get a Fast & Accurate Quote

Fill in your requirements below, and our engineers will respond within 24 hours.
Name *
Email *
Message
Get a free Quote
Name *
Email *
Message
Message Us