Product Details
Description
ProcessMaster Water FEW620 – A good fit for Standard applications in water & wastewater industries.
Equipped with all necessary functions
- Sensor Coil and electrode diagnostic keep your process up and running
– Detecting critical process conditions at an early stage reduce unscheduled downtime and maintenance
– Clear text messages simplify troubleshooting
- In-built noise/grounding check
– Verify the installation is correct from day one
– Checks for proper grounding which is fundamental to an accurate flow measurement
- In-built verification for highest confidence in your flow measurement
– Checking for sensor and transmitter integrity
– No need to remove the flowmeter from the process
- Sensor Memory Technology ensures Simplicity of operation
– Automatic self-configuration sequence
– Incredibly easy to work with
- Option for Modbus RTU communication
– For more Data from the Device and the process
– 4-20mA and Modbus in prallel at the same time
Specification
General specifications:
- Measuring value error
– Standard 0.4 % of rate, option for 0.3% of rate
- Nominal diameter
– DN 25 to 3000 (1 to 120 in.)
- Process connection
– Flange based on ISO, ASME, JIS, AS2129 table D, E, AWWA C207
- Nominal pressure
–PN 6 to 40; ASME CL 150, 300 JIS 5K, 20K, AS PN16, 35, AWWA C207 Class B, D, E
- Lining
– Hard rubber
- IP rating
– IP67, IP68, NEMA4x
- Fluid temperature
– min.: -5°C (23 °F) max.: 80 °C (176 °F)
- Communication
– 4…20mA / HART
– Modbus RTU
– 4…20mA in parallel to Modbus
- Ex approvals
– ATEX, IECEx, cFMus
- Process diagnostics
– Empty pipe, Electrode-Impedance